Improve the reliability of SBS bitumen emulsion plants: Once you have an established maintenance, it will help to identify problems. This will allow the maintenance plan and time to be carried out at your convenience. Regular maintenance will increase the normal operation time of SBS bitumen emulsification equipment, and it can be used when necessary. Low cost of operation: Imagine an SBS bitumen emulsification plant breaks down during a project. With a protective maintenance plan, such things happen less often because you have taken good care of the SBS bitumen emulsification plant.
If the SBS bitumen emulsification plant wants to maintain normal operation, then in the production process. All stages need to be maintained normal, among which the normality of the circuit system is an important aspect to ensure its smooth operation. Imagine that if there is a problem with the circuit during the on-site operation, it may affect the development of the entire project.
For users, of course, they don’t expect this to happen, so if the SBS bitumen emulsification plant is in the work of using the SBS bitumen emulsification equipment, if there is a circuit problem, it is necessary to take appropriate measures to solve it in time. The following article will give a detailed description of this problem, and the following SBS bitumen emulsification plant can be of benefit to everyone.

Rated 4.8/5 based on 524 customer reviews
Share:
Content

Improve the reliability of SBS bitumen emulsion plants: Once you have an established maintenance, it will help to identify problems. This will allow the maintenance plan and time to be carried out at your convenience. Regular maintenance will increase the normal operation time of SBS bitumen emulsification equipment, and it can be used when necessary. Low cost of operation: Imagine an SBS bitumen emulsification plant breaks down during a project. With a protective maintenance plan, such things happen less often because you have taken good care of the SBS bitumen emulsification plant.
If the SBS bitumen emulsification plant wants to maintain normal operation, then in the production process. All stages need to be maintained normal, among which the normality of the circuit system is an important aspect to ensure its smooth operation. Imagine that if there is a problem with the circuit during the on-site operation, it may affect the development of the entire project.
For users, of course, they don’t expect this to happen, so if the SBS bitumen emulsification plant is in the work of using the SBS bitumen emulsification equipment, if there is a circuit problem, it is necessary to take appropriate measures to solve it in time. The following article will give a detailed description of this problem, and the following SBS bitumen emulsification plant can be of benefit to everyone.
Judging from many years of production experience, there are often some problems in the operation of bitumen concrete mixing plants, which are usually caused by solenoid problems and circuit problems. Therefore, in the actual production work of SBS bitumen emulsification plants, it is necessary to distinguish these two different problems and adopt appropriate solutions to solve them respectively.
If the SBS bitumen emulsification equipment finds that the fault is caused by the solenoid coil after checking the SBS bitumen emulsification equipments, then the SBS bitumen emulsification plants should first use the electric meter to check. The actual method content is: connect the voltage of the test instrument to the solenoid coil, and the SBS bitumen emulsification plant measures the actual value of the voltage. If it is consistent with the standard value, it proves that the solenoid coil is normal.
If it is inconsistent with the standard value, the SBS bitumen emulsification equipment needs to be checked again, for example, it is necessary to check whether the power supply and other power generation circuits are abnormal, and make good solutions.
If it is another reason, then the SBS bitumen emulsification equipment also needs to be judged by measuring the actual voltage status of the SBS bitumen emulsification equipments. The actual method is: turn the hydraulic reversing valve. If it can still turn normally under the required voltage conditions, it means that the heater is faulty and needs to be solved. Otherwise, it means that the circuit is normal and the magnetic coil of the bitumen concrete mixing station should be inspected accordingly.