Tips for repairing circuit failures in asphalt mixing plants
Release Time:2024-11-19
Read:
Share:
If the asphalt mixing plant wants to maintain normal operation, then during the processing, the key links must be maintained normal. Among them, the normal operation of the electronic control system is a key aspect to ensure its smooth operation. Imagine that if there is a problem with the power circuit during the actual construction of the asphalt mixing plant, then it may affect the progress of the entire project.
For customers, of course, they don’t want this to happen, so if there is a power circuit problem in the work of the asphalt mixing plant, they must take appropriate measures to solve it in time. The following article will describe this problem in detail, and I will help you.
asphalt mixing plantsasphalt mixing plants
From many years of production experience, in the work of asphalt mixing plants, some common faults often occur, which are generally caused by coil problems and power circuit problems. Therefore, in our actual production work, we must distinguish these two different common faults and take appropriate solutions to solve them respectively.
If we find that the fault is caused by the coil after checking the asphalt mixing plant, we should first use the meter to check. The actual method is: connect the test instrument to the voltage of the coil, accurately measure the actual value of the voltage, if it is consistent with the standard value, then it proves that the coil is normal. If it is inconsistent with the standard value, we need to continue to check, for example, we need to check whether the power supply and other generating circuits are abnormal, and solve them.
If it is the second reason, then we also need to distinguish by measuring the actual voltage status. The actual method is: turn the hydraulic reversing valve, if it can still turn normally under the required voltage standard, then it means that it is a problem with the heating furnace and needs to be solved. Otherwise, it means that the power circuit is normal, and the electromagnetic coil of the asphalt mixing plant should be inspected accordingly.
It should be noted that no matter what kind of common fault it is, we should ask professional personnel to inspect and solve it, so as to ensure the safety of operation and help maintain the safety and smoothness of the asphalt mixing plant.